A spring impact hammer is a stored-energy device. The energy is set by how far the spring is compressed, released by a mechanical latch, and delivered through a hammer head to the enclosure. Everything about the test depends on that latch releasing at the same point every time, and on the head being the right shape. Both are verifiable, and neither is verified as often as it should be.
The energy ladder
IEC 60068-2-75 defines a series of preferred energies, and product standards select from it. The ladder is geometric, which makes the gaps predictable:
| Energy (J) | 0.14 | 0.2 | 0.35 | 0.5 | 0.7 | 1.0 | 2.0 |
| Typical use | Light covers | Handheld parts | Enclosure walls | Portable parts | Fixed parts | Robust enclosures | Heavy equipment |
The energies correspond to the IK code numbers used for enclosures, and the correspondence is not one-to-one with the code digit; a product standard states which energy applies to which part. Testing everything at 2 J to be safe is not a stricter test, it is a different test, and it produces failures the product was never required to survive.
Why the release point is the whole instrument
The spring is compressed until a latch trips. The energy delivered is the integral of force over the compression distance at the moment of release. If the latch trips 2 mm early, the hammer delivers less than the stamped energy, and the instrument still reads as a 0.5 J hammer on its label.
Verification options, in increasing order of effort:
- Drop-height comparison. Compare the hammer's effect on a reference specimen with a known falling mass. Crude, but catches gross errors.
- Force-time measurement. A calibrated force transducer on a rigid anvil records the impact pulse; the area under the curve is the energy. This is the method most calibration laboratories use.
- Pendulum comparison. A reference pendulum with known energy and a matched head profile.
Whichever method is used, the record must state the energy actually delivered, not the nominal. A hammer that measures 0.46 J at a 0.5 J setting is still usable for most product standards if the tolerance is ±10 percent, but the report should say so.
Release technique changes the result
The hammer is held against the specimen, then released. Three operator habits cause most of the scatter between laboratories:
- Pushing while releasing. Any forward push adds energy. The hammer should be positioned, then released without moving the hand.
- Holding the hammer off the surface. A gap lets the hammer accelerate before contact, which adds energy and changes the pulse shape.
- Not holding square. An angled strike puts a bending component into the enclosure and produces cracking at loads the part was not designed to resist.
The three-strike rule exists to catch the difference between a part that survives once and a part that survives service. Strikes are placed on the weakest points identified by inspection, not distributed evenly, and the same point is struck three times.
Reading the result
Acceptance after an impact test is not "no damage". The usual criteria are that the part shall not show damage that would impair safety, shall not expose live parts, and shall continue to meet the creepage and clearance requirements of the product standard. Three findings are worth separating:
- Crack through a wall that leaves a live part accessible — a fail regardless of appearance.
- Dent or local deformation that reduces a clearance below the required value — a fail that is invisible without measurement.
- Cosmetic damage with no functional or safety consequence — a pass, and worth recording as such so it is not re-litigated.
Harness and specimen support
A portable product is tested as it would be used, which usually means unsupported. A fixed product is mounted as it would be installed. The difference is large: a wall-mounted enclosure backed by a rigid steel plate will pass energies that the same enclosure fails when mounted on a plasterboard jig. The mounting is part of the test condition and belongs in the report.
The impact testing range covers spring hammers from 0.14 J to 2 J with matched heads and verification anvils; the catalogue indexes the pendulum equipment used for higher energies.