Test probe 12 sits between two extremes. It is too thin to model a finger and too thick to model a wire. It exists because a specific size of opening exists in real products: a ventilation slot, a seam, a connector recess that a finger cannot enter but a small tool can.
Dimensions and what they mean
The probe is a 4 mm rod with a 25 mm stop face. The rod length is 100 mm, which defines the maximum reach; the stop face is smaller than the 50 mm face on probes 11 and B, because the openings it tests are in tighter geometry where a large disc would not seat.
| Probe | Rod | Stop face | Models |
|---|---|---|---|
| 11 | 12 mm | 50 mm | a finger |
| 12 | 4 mm | 25 mm | a small tool or pin |
| 17 | 0.5 mm | small | a wire or lead |
The reach question
The 100 mm rod length is not arbitrary. It represents how far a small object can be pushed into an opening by hand before the geometry or the object's own stiffness stops it. A shorter probe would under-test; a longer one would model a tool the standard does not assume.
When the probe enters a slot and reaches a barrier at 60 mm, the barrier is within the assumed reach, and the question becomes whether the probe can be angled to bypass it. That is where the stop face matters: it prevents the operator from pushing the probe past the point where a real object would be stopped.
Where probe 12 is required
It is specified by product standards for openings that a finger cannot enter but which lead toward live parts. Ventilation arrays, the gap between a switch actuator and its bezel, seams between mouldings that flex under load, and the recess around a connector.
It is not automatically required everywhere. Using it on every product produces failures the standard never asked about, and a report full of such findings loses credibility.
Three practical problems
Angling. Probe 12 is straight and rigid. When the standard intends the probe to follow a contour, a straight rod cannot. The operator has to judge how much angling is legitimate, and two operators will judge differently. Writing down the angles attempted makes the result reproducible.
Bending. A 4 mm rod is stiff enough to resist normal handling but will bend if forced. A bent rod changes its effective reach and its entry angle. Check straightness by rolling on a flat surface.
The stop face in tight geometry. The 25 mm disc will not seat in a narrow recess, so the insertion depth is not controlled by the face and becomes operator-dependent. On such geometry, mark the rod at the depth the face would have allowed, so the depth is still defined.
Recording the result
Record which opening was tested (with a photograph), the force applied, the depth reached, and whether the probe was angled to bypass any internal barrier. The angling detail is what makes a "not accessible" verdict defensible.
An "accessible" result on probe 12 is a stronger finding than one on probe 11, because the object it models is more likely to be present in a domestic environment — a small tool, a piece of wire, a paper clip. Those results deserve a photograph and a clear note of the path the probe took.