Between the adult finger probe and the thin wire probe there is a size that corresponds to a small child's finger. Probe 19 is that size, and its dimensions are not arbitrary — they come from measurements of hands at a particular age.
Dimensions
The probe has a jointed finger of about 5.6 mm diameter in three segments, with a total working length of roughly 44 mm, mounted on a handle. The joint allows it to follow a curved path the way a small finger would.
The handle is wider than the finger and acts as a stop, though on this probe the handle is also part of what the standard defines: its diameter and the way it transitions to the finger affect how deep the finger can be pressed into an opening.
| Probe | Finger diameter | Age modelled |
|---|---|---|
| B / 11 | 12 mm | adult |
| 18 | 8.6 mm | 36 months to 14 years |
| 19 | 5.6 mm | up to 36 months |
Why the smallest age group needs its own probe
A toddler's finger is not a scaled-down adult finger. It is proportionally shorter and thinner, and a child of that age explores openings differently — more by pushing than by probing.
The consequence is that openings which stop an adult finger do not stop a small one, and the depth a small finger reaches is different. Probe 19 models both the diameter and the articulation.
Where the standard requires it
It appears in product standards for equipment accessible to young children — toys, some household appliances, child-care articles. It is not a general accessibility probe and should not replace probe 11 or 18 on general equipment.
Using it on a product designed for adults produces findings the standard never asked about, and a report full of such findings is a report that gets discounted.
Practical difficulties
The joint is small and light. A 5.6 mm jointed finger is delicate. It bends under very little force, and a heavy-handed operator will fold it against a barrier and report "not accessible" when the finger would have followed the contour.
Force is specified. The force applied matters on a jointed probe more than on a rigid one, because the joint's deflection under load changes the reach. Applying a constant, calibrated force matters more here than anywhere else in the probe range.
Orientation of the joint plane. As with all jointed probes, the plane in which the finger articulates must correspond to the direction a finger would bend. Rotating the probe to make it fit is rotating the test.
Reading the result
An entry with probe 19 on a live part is a finding about a specific population, and the product standard decides what that means. On a product intended for children, it usually means the design must change. On a product not intended for them, the finding may be informative but not a nonconformity.
That distinction is worth stating explicitly in the report, because the number alone invites the wrong conclusion.
Inspection
Check the finger diameter at each segment, the total length, the joint's freedom of movement and its absence of play, and the handle dimensions. Store it in a rigid case — a jointed finger of this size does not survive a drawer.