Probe A is a 50 mm sphere with a 45 mm stop disc. It is the only probe in the range that models the back of a hand rather than a finger, and it is the only one tested at 50 N. Both facts are easy to forget, and both change what the test means.
Dimensions and what they represent
The working part is a sphere of 50 mm diameter, mounted on a disc of 45 mm diameter and 4 mm thickness. The sphere models the back of a hand — a broad, blunt shape that can rest against a surface but cannot enter a small opening.
The disc is smaller than the sphere, which is counter-intuitive until you consider its function: it limits how far the sphere can be pressed into a large opening, representing the wrist and forearm behind the hand.
| Probe | Working part | Force | IP level |
|---|---|---|---|
| A | 50 mm sphere | 50 N | IP1X |
| B | 12 mm jointed finger | 10 N / 30 N | IP2X |
Why 50 N
The force is the highest of any probe because the shape is the bluntest. A hand leaning against an enclosure applies far more force than a finger probing it, and the standard reflects that. Using 10 N with probe A under-tests a situation that happens every time someone leans on a machine.
50 N is about 5 kg. It is enough to deflect a thin plastic cover, to push a compliant gasket aside, and to open a gap that a light touch would leave closed.
What IP1X actually requires
IP1X is protection against access to hazardous parts with the back of the hand. It is a low level, and most products pass it without effort. That is exactly why it is skipped — and why a product with a large opening can fail it without anyone noticing.
The failure mode is specific: an opening large enough for the sphere, leading to a live part within the sphere's reach. A ventilation grille with wide slots, a guard removed during maintenance, a missing cover plate.
Testing it properly
Three points:
Apply force through the sphere axis. The sphere should be pressed squarely, not angled, because an angled press concentrates force on an edge and can deform a cover in a way a hand would not.
Hold the force for a defined time. A momentary press does not allow a compliant cover to deflect. The standard specifies a duration.
Check every large opening. A product with one grille tested and another not tested has been half tested, and the untested grille is usually the one added later.
Inspection
The sphere is the easiest part of the range to inspect: diameter at several points, and sphericity. The disc matters less but should be checked for flatness and for a burr on the rim, which would hold the sphere off the surface and change the depth.
A sphere with a flat spot is the common failure. It develops on probes that are stored lying on a bench and used as paperweights. A flat spot lets the probe approach closer to a live part than a true sphere would, producing a failure that is real but caused by the tool.