Probe D is a 1 mm diameter pin, 100 mm long, mounted on a 35 mm sphere. It represents a wire, a nail or a thin tool — something that reaches places a finger cannot. It is used at 1 N, and that is the lowest force in the IEC 61032 range for a rigid probe.
The three dimensions
1 mm diameter. Thin enough to enter a gap that no finger approaches. The relevant hazard is not a person poking with a finger but a piece of wire, a fastener, or a tool dropping into a slot.
100 mm length. Long enough to reach past an internal barrier and touch something the enclosure was assumed to protect.
35 mm sphere. The stop, and the representation of whatever is holding the pin — a hand gripping a wire, or the body of a tool.
| Probe | Working part | Stop | Force |
|---|---|---|---|
| C | 2.5 mm × 100 mm pin | 35 mm sphere | 3 N |
| D | 1 mm × 100 mm pin | 35 mm sphere | 1 N |
Why only 1 N
The force is low because the probe models something light. A wire or a dropped nail arrives with its own weight, not with a person's push. Applying 10 N to a 1 mm pin tests a scenario that does not occur, and it deforms the pin.
The low force is also the practical problem. A hand cannot reliably apply 1 N — it is about the weight of a small apple. Operators either press far too hard, or the probe's own weight dominates and the reading becomes meaningless.
The workable approach is a guided loading fixture or a spring with a known rate, compressed to a marked deflection. Judging 1 N by feel is not a measurement.
What a 1 mm pin finds
Three patterns recur:
Slots and louvres. A ventilation slot 1.5 mm wide admits the pin and refuses every finger probe. The question is what the pin touches 40 mm inside.
Seams between mouldings. A joint with a 1.2 mm gap along part of its length is a path for a pin and for nothing else. These gaps open and close with temperature, so a cold product may show nothing.
Holes for fasteners. A screw hole that does not reach the internal cavity is safe; a hole that breaks into it is a path, and the pin finds it in one motion.
Distinguishing probe C and probe D
The two differ only in diameter and force, and both carry the same 35 mm sphere. Probe C is 2.5 mm at 3 N; probe D is 1 mm at 1 N. In the ingress-protection system they correspond to IP3X and IP4X respectively.
A product that passes IP3X and is claimed for IP4X has been tested with the wrong pin, and the difference is exactly the range of gaps between 1 mm and 2.5 mm — which is where most moulding tolerances live.
Inspecting the pin
A 1 mm pin is the most easily damaged tool in the kit, and the damage is invisible without magnification:
Bend. Roll on a surface plate; even a slight bow changes the direction of entry over 100 mm of length.
Tip condition. A rounded or flattened tip will not enter a slot the original could, which produces a pass where a failure exists. Look at the tip under 10× magnification.
Diameter. Measure at three points. A pin worn to 0.95 mm is no longer testing a 1 mm opening.
Sphere seating. A loose sphere changes the stop position, and therefore the depth reached.
Recording the result
For each opening tested: the probe, the force, the depth reached, and whether contact was made with a hazardous part. Photograph the opening with a scale — a 1 mm gap is not visible in a general view, and a report that says "probe D could not enter" without showing the gap cannot be checked.