Probe 13 is the one in the kit that nobody recognises. It is not a rod and not a finger: it is a short conical pin, 3 mm at one end and 4 mm at the other, 15 mm long, on a 25 mm disc. It exists for a specific class of product, and using it outside that class produces results that mean nothing.
The dimensions
The working part is a tapered pin with defined diameters at each end and a defined length. The taper is the point: it models a tool or a wire end that is not a perfect cylinder, and it enters an opening progressively rather than at a fixed diameter.
The 25 mm disc of 4 mm thickness is the stop, and it is the same disc used on probe 12 — small enough to reach into a recess that a 50 mm disc cannot enter.
| Probe | Working part | Disc |
|---|---|---|
| 13 | tapered pin 3 to 4 mm, 15 mm | 25 mm x 4 mm |
| 12 | straight rod 4 mm, 50 mm | 25 mm x 4 mm |
What it is for
Probe 13 is associated with the assessment of access to live parts in products where the relevant standard distinguishes classes of protection. It appears in the probe family used for the Class 0 and Class II cases rather than in the generic ingress-protection sequence.
That association matters. The probe is not part of the IP1X to IP4X ladder, and a report that lists it alongside probes A to D as though it were another IP level has misunderstood the family.
Why a taper instead of a cylinder
A cylindrical probe answers a binary question: does a 4 mm rod enter? A tapered probe answers a graduated one: how far does a 4 mm to 3 mm taper enter before it is stopped?
That is useful where the opening is not a clean slot but a gap that varies — a seam with a taper, a moulded aperture with draft, a joint that is wider at one end. A cylinder either enters or does not; a taper reports the width.
Reading the result
The insertion depth is the measurement, not a pass or fail on entry. A taper that enters 5 mm has found an opening roughly 3.5 mm wide at the surface; one that enters 10 mm has found something closer to 4 mm.
That is why the report needs the depth. A result of "probe 13 could not enter" and one of "probe 13 entered 2 mm" describe different products, and only one of them is likely to be acceptable.
The disc does the limiting
On a recessed aperture, the disc seats on the surrounding surface and stops the taper at a fixed depth regardless of the opening. The operator then reads whether the taper reached a live part at that depth.
If the disc cannot seat — because the surrounding surface is curved or has a raised lip — the depth is uncontrolled and the result is not comparable with a properly seated test. Record the seating, not just the depth.
Inspection
The taper is the most easily damaged working surface in the kit, because it is short and has a fine edge at the small end.
End diameters. Measure both ends. Wear at the small end is expected and it changes the taper angle, which changes the depth reading.
Straightness of the taper. A bent taper reads deeper on one side. Roll it on a surface plate and look for a wobble.
The transition to the disc. A burr at the root holds the taper off the surface and prevents the disc from seating.
Disc squareness. A disc that is not perpendicular to the taper tilts the probe and biases the depth.
What to record
Probe identity, insertion depth, whether the disc seated, and the condition of the surface at the opening. Four fields. The one that is always missing is the seating, and without it a depth reading cannot be interpreted.